Vui lòng điền thông tin bên dưới để hỏi về FIE Biến tần vector vòng kín cao cấp thế hệ mới




    Technical specifications of the FIE

    ItemSpecifications
    Standard

    functions

    Maximum

    frequency

    • Vector control: 0–300 Hz• V/F control: 0–320 Hz
    Carrier

    Frequency

    0.5–16 kHz

    The carrier frequency is automatically adjusted based on the load features.

    Input frequency

    Resolution

    Digital setting: 0.01 Hz

    Analog setting: maximum frequency x 0.025%

    Control mode• Sensorless flux vector control (SFVC)

    • Closed-loop vector control (CLVC)

    • Voltage/Frequency (V/F) control

    Startup torque• G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC)

    • P type: 0.5 Hz/100%

    Speed range1:100 (SVC)        1:1000 (FVC)
    Speed stability±0.5% (SVC)       ±0.02% (FVC)
    Torque control±5% (FVC)
    Overload

    capacity

    • G type: 60sor 150% of the rated current, 3s for 180% of the rated current

    • P type: 60s for 120% of the rated current, 3s for 150% of the rated current

    Torque boost• Fixed boost• Customized boost 0.1%–30.0%
    V/F curve• Straight-line V/F curve• Multi-point V/F curve

    • N-power V/F curve (1.2-power, 1.4-power, 1.6-power,1.8-power,square)

    V/F separationTwo types: complete separation; half separation
    Ramp mode• Straight-line ramp• S-curve ramp

    Four groups of acceleration/deceleration time with the range of 0.0–6500.0s

    DC brakingDC braking frequency: 0.00 Hz to maximum frequency

    Braking time: 0.0–36.0s

    Braking action current value: 0.0%–100.0%

    JOG controlJOG frequency range: 0.00–50.00 Hz

    JOG acceleration/deceleration time: 0.0–6500.0s

    Onboard

    multiple preset

    It implements up to 16 speeds via the simple PLC function or combination

    of DI terminal states.

    Onboard PIDIt realizes process-controlled closed loop control system easily.
    Auto voltage

    regulation

    It can keep constant output voltage automatically when the mains voltage

    changes.

    Over voltage/

    Over current

    stall Control

    The current and voltage are limited automatically during the running

    process so as to avoid frequent tripping due to over voltage/over current.

    Fast current

    limiting function

    Minimizing over-current fault protect the normal operation of the inverter
    Torque limit and

    control

    It can limit the torque automatically and prevent frequent over current

    tripping during the running process.

    Torque control can be implemented in the CLVC mode.

    Individualized

    functions

    High

    performance

    Control of asynchronous motor and synchronous motor are implemented

    through the high-performance current vector control technology.

    Power dip ride

    Through

    The load feedback energy compensates the voltage reduction so that the

    AC drive can continue to run for a short time.

    Rapid current

    limit

    It helps to avoid frequent over current faults of the AC drive.
    Virtual I/OsFive groups of virtual DI/Dos can realize simple logic control.
    Timing controlTime range: 0.0–6500.0 minutes
    Multi-motor

    switchover

    Four motors can be switched over via four groups of motor parameters.
    Multiple

    communication

    It supports communication via Modbus -RTU, PROFIBUSDP, CAN link

    and CAN open.

    Motor overheat

    Protection

    The optional I/O extension card enables AI3 to receive the motor

    temperature sensor input (PT100, PT1000) so as to realize motor

    overheat protection.

    Multiple encoder

    Types

    It supports various encoders such as differential encoder, open-collector

    encoder, resolver, UVW encoder, and SIN/COS encoder.

    RUNRunning

    command source

    • Operation panel • Control terminals • Serial communication port

    You can perform switchover between these sources in various ways.

    Frequency sourceThere are a total of 10 frequency sources, such as digital setting, analog

    voltage setting, analog current setting, pulse setting and serial

    communication port setting.

    You can perform switchover between these sources in various ways.

    Auxiliary

    frequency source

    There are ten auxiliary frequency sources. It can implement fine tuning of

    auxiliary frequency and frequency synthesis.

    Input terminalStandard:

    5 digital input (DI) terminals, one of which supports up to

    100 kHz high-speed pulse input

    2 analog input (AI) terminals, one of which only supports

    0–10 V voltage input and the other supports 0–10 V voltage

    input or 4–20 m A current input

    Expanding capacity:

    5 DI terminals

    1 AI terminal that supports -10–10 V voltage input and also

    supports PT100\PT1000

    Output terminalStandard

    1 high-speed pulse output terminal (open-collector) that

    supports 0–100 kHz square wave signal output

    1 digital output (DO) terminal

    1 relay output terminal

    1 analog output (AO) terminal that supports 0–20 m A

    current output or 0–10 V voltage output

    Expanding capacity:

    1 DO terminal

    1 relay output terminal

    1 AO terminal that supports 0–20 m A current output or 0–10

    V voltage output

    Display and

    operation on

    the operation

    panel

    LED displayIt displays the parameters.
    LCD displayingOptional parts, Chinese/English Prompt action content
    Parameters of the

    copy

    Achieved through the LCD operation panel option parameters of rapid

    replication

    Key locking and

    function selection

    It can lock the keys partially or completely and define the function range of

    some keys so as to prevent mis-function.

    Protection modeMotor short-circuit detection at power-on, input/output phase loss

    protection, over current protection, over voltage protection, under voltage

    protection, overheat protection and overload protection

    EnvironmentInstallation

    Location

    Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil

    smoke, vapour, drip or salt.

    AltitudeLower than 1000 m
    Ambient

    Temperature

    -10°C to +40°C (de-rated if the ambient temperature is between 40°C and

    50°C)

    HumidityLess than 95%RH, without condensing
    VibrationLess than 5.9 m/s2 (0.6 g)
    Storage Temperature-- 20℃ ~ + 60℃
    IP levelIP20
    Pollution degreePD2
    Power distribution

    System

    TN , TT

    Mọi yêu cầu hỗ trợ kỹ thuật về sản phẩm và cũng như yêu cầu báo giá vui lòng liên hệ theo thông tin:

    Mr Bụi : 0938 416 567 – 0909 629 558

    Email: Buinvt@gmail.com